Alarm Solutions Search hear ...

Servo Amplifier Alarms
SV0001 SYNC ALIGNMENT ERROR
In feed axis control , the amount of compensation for synchronization exceeded the parameter (No. 8325) setting value.This alarm occurs…
SV0002 SYNC EXCESS ERROR ALARM 2
In feed axis control , the amount of synchronization error exceeded the parameter (No. 8332) setting value. When the synchronization…
SV0003 SYNCHRONOUS/COMPOSITE/SUPER IMPOSED CONTROL MODE CAN’T BE CONTINUED
Since as axis in synchronization, composite, or superimposed mode caused a servo alarm, the mode could not be continued, If…
SV0004 EXCESS ERROR (G31)
The amount of positional deviation during torque limit skip command operation exceeded the limit value of the parameter No.6287.
SV0005 SYNC EXCESS ERROR (MCN)
In feed axis control , for synchronization, the difference value of the machine coordinate between a master and slave axes…
SV0006 ILLEGAL TANDEM AXIS
For the slave axis under tandem control, absolute position detection is set (parameter bit 5 (APC) of parameter No. 1815…
SV0007 SV ALM ANOTHER PATH(MULTI AMP.)
When a multiaxis amplifier was used in a 2-path system across paths, a servo alarm occurred on an axis belongingto…
SV0301 APC ALARM: COMMUNICATION ERROR
Since the absolute-position detector caused a communication error, the correct machine position couldnot be obtained. (data transfer error) The absolute-position…
SV0302 APC ALARM: OVER TIME ERROR
Since the absolute-position detector caused an overtime error, the correct machine position could not be obtained.(data transfer error) The absolute-position…
SV0303 APC ALARM: FRAMING ERROR
Since the absolute-position detector caused a framing error, the correct machine position could not be obtained.(data transfer error)The absolute-position detector,…
SV0304 APC ALARM: PARITY ERROR
Since the absolute-position detector caused a parity error, the correct machine position could not be obtained. (datatransfer error)The absolute-position detector,…
SV0305 APC ALARM: PULSE ERROR
Since the absolute-position detector caused a pulse error, the correct machine position could not be obtained. The absolute-position detector, or…
SV0306 APC ALARM: OVER FLOW ERROR
SV0306 APC ALARM: OVER FLOW ERROR - Since the amount of positional deviation overflowed, the correct machine position could not…
SV0307 APC ALARM: MOVEMENT EXCESS ERROR
SV0307 APC ALARM: MOVEMENT EXCESS ERROR - Since the machine moved excessively, the correct machine position could not be obtained.
SV0360 ABNORMAL CHECKSUM(INT)
SV0360 ABNORMAL CHECKSUM(INT) - The checksum alarm occurred on the built–in Pulsecoder.
SV0361 ABNORMAL PHASE DATA(INT)
SV0361 ABNORMAL PHASE DATA(INT) - The phase data abnormal alarm occurred on the built–in Pulse coder.
SV0362 ABNORMAL REV. DATA(INT)
SV0362 ABNORMAL REV. DATA(INT) The speed count abnormal alarm occurred on the built-in Pulsecoder.
SV0363 ABNORMAL CLOCK(INT)
SV0363 ABNORMAL CLOCK(INT) - The clock alarm occurred on the built–in Pulsecoder.
SV0364 SOFT PHASE ALARM(INT)
SV0364 SOFT PHASE ALARM(INT) - A digital servo soft detected an abnormality on the built in Pulsecoder.
SV0365 BROKEN LED(INT)
SV0365 BROKEN LED(INT) - The digital servo software detected abnormal data on thebuilt–in Pulsecoder.
SV0366 PULSE MISS(INT)
SV0366 PULSE MISS(INT) - A pulse error occurred on the built–in Pulsecoder.
SV0367 COUNT MISS(INT)
SV0367 COUNT MISS(INT) - A count error occurred on the built–in Pulsecoder.
SV0368 SERIAL DATA ERROR(INT)
SV0368 SERIAL DATA ERROR(INT) - The communications data could not be received from thebuilt–in Pulsecoder.
SV0369 DATA TRANS. ERROR(INT)
SV0369 DATA TRANS. ERROR(INT) - A CRC error or stop bit error occurred in the communications data from the built–in…
SV0380 BROKEN LED(EXT)
SV0380 BROKEN LED(EXT) - SV0380 BROKEN LED(EXT)
SV0381 ABNORMAL PHASE (EXT)
SV0381 ABNORMAL PHASE (EXT) - An abnormal alarm in the position data occurred on theseparate detector.
SV0382 COUNT MISS(EXT)
SV0382 COUNT MISS(EXT) A count error occurred on the separate detector.
SV0383 PULSE MISS(EXT)
SV0383 PULSE MISS(EXT) A pulse error occurred on the separate detector.
SV0384 SOFT PHASE ALARM(EXT)
SV0384 SOFT PHASE ALARM(EXT) - The digital servo software detected abnormal data on theseparate detector.
SV0385 SERIAL DATA ERROR(EXT)
SV0385 SERIAL DATA ERROR(EXT) - The communications data could not be received from theseparate detector.
SV0386 DATA TRANS. ERROR(EXT)
SV0386 DATA TRANS. ERROR(EXT) A CRC error or stop bit error occurred in the communications data from the standalone detector.
SV0387 ABNORMAL ENCODER(EXT)
SV0387 ABNORMAL ENCODER(EXT) An abnormality occurred on a separate detector. For moreinformation, contact the scale manufacturer.
Servo alarms (SV alarm) SV0401 Solutions
Servo alarms (SV alarm) SV0401 Message - SV0401 IMPROPER V_READY OFF Description Although the ready signal (PRDY) of the position…
Servo alarms (SV alarm) SV0403 Solutions
Servo alarms (SV alarm) SV0403 Message - SV0403 CARD/SOFT MISMATCH Description The combination of the axis card and the servo…
Servo alarms (SV alarm) SV0404 Solutions
Servo alarms (SV alarm) SV0404 Message - SV0404 IMPROPER V_READY ON Description Although the ready signal (PRDY) of the position…
Servo alarms (SV alarm) SV0407 Solutions
Servo alarms (SV alarm) SV0407 Message - SV0407 EXCESS ERROR Description The difference value of the amount of positional deviation…
Servo alarms (SV alarm) SV0409 Solutions
Servo alarms (SV alarm) SV0409 Message - SV0409 DETECT ABNORMAL TORQUE Description An abnormal load was detected on the servo…
Servo alarms (SV alarm) SV0410 Solutions
Servo alarms (SV alarm) SV0410 Message - SV0410 EXCESS ERROR (STOP) Description The amount of positional deviation during stopping exceeded…
Servo alarms (SV alarm) SV0411 Solutions
Servo alarms (SV alarm) SV0411 Message - SV0411 EXCESS ERROR (MOVING) Description The amount of positional deviation during traveling became…
Servo alarms (SV alarm) SV0413 Solutions
Servo alarms (SV alarm) SV0413 Message - SV0413 LSI OVERFLOW Description The counter for the amount of positional deviation overflowed…
Servo alarms (SV alarm) SV0415 Solutions
Servo alarms (SV alarm) SV0415 Message - SV0415 MOTION VALUE OVERFLOW Description The velocity exceeding the travel velocity limit was…
Servo alarms (SV alarm) SV0417 Solutions
Servo alarms (SV alarm) SV0417 Message - SV0417 ILL DGTL SERVO PARAMETER Description A digital serve parameter setting is incorrect.…
Servo alarms (SV alarm) SV0420 Solutions
Servo alarms (SV alarm) SV0420 Message - SV0420 SYNC TORQUE EXCESS Description In feed axis control , for synchronization, the…
Servo alarms (SV alarm) SV0421 Solutions
Servo alarms (SV alarm) SV0421 Message - SV0421 EXCESS ERROR(SEMI-FULL) Description The difference between the feedback from the semi and…
Servo alarms (SV alarm) SV0422 Solutions
Servo alarms (SV alarm) SV0422 Message - SV0422 EXCESS VELOCITY IN TORQUE Description In torque control, the commanded permissible velocity…
Servo alarms (SV alarm) SV0423 Solutions
Servo alarms (SV alarm) SV0423 Message - SV0423 EXCESS ERROR IN TORQUE Description In torque control, the total permissible move…
Servo alarms (SV alarm) SV0430 Solutions
Servo alarms (SV alarm) SV0430 Message - SV0430 SV MOTOR OVERHEAT Description The servo motor has overheated. Drive ( Amplifier…
Servo alarms (SV alarm) SV0431 Solutions
Servo alarms (SV alarm) SV0431 Message - SV0431 CNV. OVERLOAD Description Power Supply (PS) : Overheat Servo Amplifier : Overheat…
Servo alarms (SV alarm) SV0432 Solutions
Servo alarms (SV alarm) SV0432 Message - SV0432 CNV. LOW VOLT CONTROL Description Power Supply (PS) : The control power…
Servo alarms (SV alarm) SV0433 Solutions
Servo alarms (SV alarm) SV0433 Message - SV0433 CNV. LOW VOLT DC LINK Description Power Supply (PS) : Low DC…
Servo alarms (SV alarm) SV0434 Solutions
Servo alarms (SV alarm) SV0434 Message - SV0434 INV. LOW VOLT CONTROL Description Servo Amplifier Drive ( Amplifier ) lowest…
Servo alarms (SV alarm) SV0435 Solutions
Servo alarms (SV alarm) SV0435 Message - SV0435 INV. LOW VOLT DC LINK Description Servo Amplifier Drive ( Amplifier )…
Servo alarms (SV alarm) SV0436 Solutions
Servo alarms (SV alarm) SV0436 Message - SV0436 SOFTTHERMAL(OVC) Description The digital servo software detected a software thermal (OVC). Drive…
Servo alarms (SV alarm) SV0437 Solutions
Servo alarms (SV alarm) SV0437 Message - SV0437 CNV. OVERCURRENT POWER Description Power Supply (PS) : Overcurrent on input circuit…
Servo alarms (SV alarm) SV0438 Solutions
Servo alarms (SV alarm) SV0438 Message - SV0438 INV. ABNORMAL CURRENT Description Servo Amplifier Drive ( Amplifier ) lowest Repair…
Servo alarms (SV alarm) SV0439 Solutions
Servo alarms (SV alarm) SV0439 Message - SV0439 CNV. OVER VOLT DC LINK Description Power Supply (PS) : The DC…
Servo alarms (SV alarm) SV0440 Solutions
Servo alarms (SV alarm) SV0440 Message - SV0440 CNV. EX DECELERATION POW. Description Power Supply (PS) : Excessive generative discharge…
Servo alarms (SV alarm) SV0441 Solutions
Servo alarms (SV alarm) SV0441 Message - SV0441 ABNORMAL CURRENT OFFSET Description The digital servo software detected an abnormality in…
Servo alarms (SV alarm) SV0442 Solutions
Servo alarms (SV alarm) SV0442 Message - SV0442 CNV. CHARGE FAILURE Description Power Supply (PS) : The spare charge circuit…
Servo alarms (SV alarm) SV0443 Solutions
Servo alarms (SV alarm) SV0443 Message - SV0443 CNV. COOLING FAN FAILURE Description Power Supply (PS) : Internal cooling fan…
Servo alarms (SV alarm) SV0444 Solutions
Servo alarms (SV alarm) SV0444 Message - SV0444 INV. COOLING FAN FAILURE Description Servo Amplifier : Internal cooling fan failure.…
Servo alarms (SV alarm) SV0445 Solutions
Servo alarms (SV alarm) SV0445 Message - SV0445 SOFT DISCONNECT ALARM Description The digital servo software detected a disconnected Pulsecoder.…
Servo alarms (SV alarm) SV0446 Solutions
Servo alarms (SV alarm) SV0446 Message - SV0446 HARD DISCONNECT ALARM Description The hardware detected a disconnected built–in Pulsecoder. Drive…
Servo alarms (SV alarm) SV0447 Solutions
Servo alarms (SV alarm) SV0447 Message - SV0447 HARD DISCONNECT(EXT) Description The hardware detected a disconnected separate detector. Drive (…
Servo alarms (SV alarm) SV0448 Solutions
Servo alarms (SV alarm) SV0448 Message - SV0448 UNMATCHED FEEDBACK ALARM Description The sign of the feedback signal from the…
Servo alarms (SV alarm) SV0449 Solutions
Servo alarms (SV alarm) SV0449 Message - SV0449 INV. IPM ALARM Description Servo Amplifier : The IPM (Intelligent Power Module)detected…
Servo alarms (SV alarm) SV0453 Solutions
Servo alarms (SV alarm) SV0453 Message - SV0453 SPC SOFT DISCONNECT ALARM Description Software disconnection alarm of the Pulsecoder.Turn…
Servo alarms (SV alarm) SV0454 Solutions
Servo alarms (SV alarm) SV0454 Message - SV0454 ILLEGAL ROTOR POS DETECT Description The magnetic pole detection function terminated abnormally.The…
Servo alarms (SV alarm) SV0456 Solutions
Servo alarms (SV alarm) SV0456 Message - SV0456 ILLEGAL CURRENT LOOP Description An attempt was made to set the current…
Servo alarms (SV alarm) SV0458 Solutions
Servo alarms (SV alarm) SV0458 Message - SV0458 CURRENT LOOP ERROR Description The specified current loop differs from the actual…
Servo alarms (SV alarm) SV0459 Solutions
Servo alarms (SV alarm) SV0459 Message - SV0459 HI HRV SETTING ERROR Description For two axes whose servo axis numbers…
Servo alarms (SV alarm) SV0460 Solutions
Servo alarms (SV alarm) SV0460 Message - SV0460 FSSB DISCONNECT Description The FSSB connection was discontinued. Probable causes are:1) The…
Servo alarms (SV alarm) SV0462 Solutions
Servo alarms (SV alarm) SV0462 Message - SV0462 SEND CNC DATA FAILED Description The correct data could not be received…
Servo alarms (SV alarm) SV0463 Solutions
Servo alarms (SV alarm) SV0463 Message - SV0463 SEND SLAVE DATA FAILED Description The correct data could not be received…
Servo alarms (SV alarm) SV0465 Solutions
Servo alarms (SV alarm) SV0465 Message - SV0465 READ ID DATA FAILED Description A read of the ID information for…
Servo alarms (SV alarm) SV0466 Solutions
Servo alarms (SV alarm) SV0466 Message - SV0466 MOTOR/AMP. COMBINATION Description The maximum current of an amplifier is different to…
Servo alarms (SV alarm) SV0468 Solutions
Servo alarms (SV alarm) SV0468 Message - SV0468 HI HRV SETTING ERROR(AMP) Description An attempt was made to set up…
Servo alarms (SV alarm) SV0600 Solutions
Servo alarms (SV alarm) SV0600 Message - SV0600 INV. DC LINK OVER CURRENT Description DC link overcurrent. Drive ( Amplifier…
Servo alarms (SV alarm) SV0601 Solutions
Servo alarms (SV alarm) SV0601 Message - SV0601 INV. RADIATOR FAN FAILURE Description External radiator cooling fan failure. Drive (…
Servo alarms (SV alarm) SV0602 Solutions
Servo alarms (SV alarm) SV0602 Message - SV0602 INV. OVERHEAT Description The servo motor has overheated. Drive ( Amplifier )…
Servo alarms (SV alarm) SV0603 Solutions
Servo alarms (SV alarm) SV0603 Message - SV0603 INV. IPM ALARM(OH) Description The IPM (Intelligent Power Module) detected an overheat…
Servo alarms (SV alarm) SV0604 Solutions
Servo alarms (SV alarm) SV0604 Message - SV0604 AMP. COMMUNICATION ERROR Description The communication between Servo amplifier and Power Supply…
Servo alarms (SV alarm) SV0605 Solutions
Servo alarms (SV alarm) SV0605 Message - SV0605 CNV. EX. DISCHARGE POW. Description Power Supply (PS) : The motor regenerative…
Servo alarms (SV alarm) SV0606 Solutions
Servo alarms (SV alarm) SV0606 Message - SV0606 CNV. RADIATOR FAN FAILURE Description Power Supply (PS) : External radiator cooling…
Servo alarms (SV alarm) SV0607 Solutions
Servo alarms (SV alarm) SV0607 Message - SV0607 CNV. SINGLE PHASE FAILURE Description Power Supply (PS) : The input power…
Servo alarms (SV alarm) SV0646 Solutions
Servo alarms (SV alarm) SV0646 Message - SV0646 ABNORMAL ANALOG SIGNAL(EXT) Description An error occurred in the analog 1Vp-p output…
Servo alarms (SV alarm) SV1025 Solutions
Servo alarms (SV alarm) SV1025 Message - SV1025 V_READY ON (INITIALIZING ) Description The ready signal (VRDY) of the velocity…
Servo alarms (SV alarm) SV1026 Solutions
Servo alarms (SV alarm) SV1026 Message - SV1026 ILLEGAL AXIS ARRANGE Description The parameter for servo axis arrange is not…
Servo alarms (SV alarm) SV1055 Solutions
Servo alarms (SV alarm) SV1055 Message - SV1055 ILLEGAL TANDEM AXIS Description In tandem control, the setting of the parameter…
Servo alarms (SV alarm) SV1056 Solutions
Servo alarms (SV alarm) SV1056 Message - SV1056 ILLEGAL TANDEM PAIR Description In tandem control, the setting of the bit…
Servo alarms (SV alarm) SV1067 Solutions
Servo alarms (SV alarm) SV1067 Message - SV1067 FSSB:CONFIGURATION ERROR(SOFT) Description An FSSB configuration error occurred (detected by software).The connected…
Servo alarms (SV alarm) SV1100 Solutions
Servo alarms (SV alarm) SV1100 Message - SV1100 S-COMP. VALUE OVERFLOW Description The amount of compensation for the simple straightness…
Servo alarms (SV alarm) SV5134 Solutions
Servo alarms (SV alarm) SV5134 Message - SV5134 FSSB:OPEN READY TIME OUT Description In the initialization, the FSSB could not…
Servo alarms (SV alarm) SV5136 Solutions
Servo alarms (SV alarm) SV5136 Message - SV5136 FSSB:NUMBER OF AMP. IS INSUFFICIENT Description The number of amplifier identified by…
Servo alarms (SV alarm) SV5137 Solutions
Servo alarms (SV alarm) SV5137 Message - SV5137 FSSB:CONFIGURATION ERROR Description An FSSB configuration error occurred.The connecting amplifier type is…
Servo alarms (SV alarm) SV5139 Solutions
Servo alarms (SV alarm) SV5139 Message - SV5139 FSSB:ERROR Description Servo initialization has not completed successfully. It is probable that…
Servo alarms (SV alarm) SV5197 Solutions
🔍 Causes of SV5197 Alarm FSSB Communication Timeout: The CNC controller expected a response from the servo amplifier but did…