Alarm Solutions Search hear ...
Servo Amplifier Alarms
Servo alarms (SV alarm) SV5197 Solutions
Servo alarms (SV alarm) SV5197 Message - SV5197 FSSB:OPEN TIME OUT Description The initialization of the FSSB was completed, but…
Servo alarms (SV alarm) SV5139 Solutions
Servo alarms (SV alarm) SV5139 Message - SV5139 FSSB:ERROR Description Servo initialization has not completed successfully. It is probable that…
Servo alarms (SV alarm) SV5137 Solutions
Servo alarms (SV alarm) SV5137 Message - SV5137 FSSB:CONFIGURATION ERROR Description An FSSB configuration error occurred.The connecting amplifier type is…
Servo alarms (SV alarm) SV5136 Solutions
Servo alarms (SV alarm) SV5136 Message - SV5136 FSSB:NUMBER OF AMP. IS INSUFFICIENT Description The number of amplifier identified by…
Servo alarms (SV alarm) SV5134 Solutions
Servo alarms (SV alarm) SV5134 Message - SV5134 FSSB:OPEN READY TIME OUT Description In the initialization, the FSSB could not…
Servo alarms (SV alarm) SV1100 Solutions
Servo alarms (SV alarm) SV1100 Message - SV1100 S-COMP. VALUE OVERFLOW Description The amount of compensation for the simple straightness…
Servo alarms (SV alarm) SV1067 Solutions
Servo alarms (SV alarm) SV1067 Message - SV1067 FSSB:CONFIGURATION ERROR(SOFT) Description An FSSB configuration error occurred (detected by software).The connected…
Servo alarms (SV alarm) SV1056 Solutions
Servo alarms (SV alarm) SV1056 Message - SV1056 ILLEGAL TANDEM PAIR Description In tandem control, the setting of the bit…
Servo alarms (SV alarm) SV1055 Solutions
Servo alarms (SV alarm) SV1055 Message - SV1055 ILLEGAL TANDEM AXIS Description In tandem control, the setting of the parameter…
Servo alarms (SV alarm) SV1026 Solutions
Servo alarms (SV alarm) SV1026 Message - SV1026 ILLEGAL AXIS ARRANGE Description The parameter for servo axis arrange is not…
Servo alarms (SV alarm) SV1025 Solutions
Servo alarms (SV alarm) SV1025 Message - SV1025 V_READY ON (INITIALIZING ) Description The ready signal (VRDY) of the velocity…
Servo alarms (SV alarm) SV0646 Solutions
Servo alarms (SV alarm) SV0646 Message - SV0646 ABNORMAL ANALOG SIGNAL(EXT) Description An error occurred in the analog 1Vp-p output…
Servo alarms (SV alarm) SV0607 Solutions
Servo alarms (SV alarm) SV0607 Message - SV0607 CNV. SINGLE PHASE FAILURE Description Power Supply (PS) : The input power…
Servo alarms (SV alarm) SV0606 Solutions
Servo alarms (SV alarm) SV0606 Message - SV0606 CNV. RADIATOR FAN FAILURE Description Power Supply (PS) : External radiator cooling…
Servo alarms (SV alarm) SV0605 Solutions
Servo alarms (SV alarm) SV0605 Message - SV0605 CNV. EX. DISCHARGE POW. Description Power Supply (PS) : The motor regenerative…
Servo alarms (SV alarm) SV0604 Solutions
Servo alarms (SV alarm) SV0604 Message - SV0604 AMP. COMMUNICATION ERROR Description The communication between Servo amplifier and Power Supply…
Servo alarms (SV alarm) SV0603 Solutions
Servo alarms (SV alarm) SV0603 Message - SV0603 INV. IPM ALARM(OH) Description The IPM (Intelligent Power Module) detected an overheat…
Servo alarms (SV alarm) SV0602 Solutions
Servo alarms (SV alarm) SV0602 Message - SV0602 INV. OVERHEAT Description The servo motor has overheated. Drive ( Amplifier )…
Servo alarms (SV alarm) SV0601 Solutions
Servo alarms (SV alarm) SV0601 Message - SV0601 INV. RADIATOR FAN FAILURE Description External radiator cooling fan failure. Drive (…
Servo alarms (SV alarm) SV0600 Solutions
Servo alarms (SV alarm) SV0600 Message - SV0600 INV. DC LINK OVER CURRENT Description DC link overcurrent. Drive ( Amplifier…
Servo alarms (SV alarm) SV0468 Solutions
Servo alarms (SV alarm) SV0468 Message - SV0468 HI HRV SETTING ERROR(AMP) Description An attempt was made to set up…
Servo alarms (SV alarm) SV0466 Solutions
Servo alarms (SV alarm) SV0466 Message - SV0466 MOTOR/AMP. COMBINATION Description The maximum current of an amplifier is different to…
Servo alarms (SV alarm) SV0465 Solutions
Servo alarms (SV alarm) SV0465 Message - SV0465 READ ID DATA FAILED Description A read of the ID information for…
Servo alarms (SV alarm) SV0463 Solutions
Servo alarms (SV alarm) SV0463 Message - SV0463 SEND SLAVE DATA FAILED Description The correct data could not be received…
Servo alarms (SV alarm) SV0462 Solutions
Servo alarms (SV alarm) SV0462 Message - SV0462 SEND CNC DATA FAILED Description The correct data could not be received…
Servo alarms (SV alarm) SV0460 Solutions
Servo alarms (SV alarm) SV0460 Message - SV0460 FSSB DISCONNECT Description The FSSB connection was discontinued. Probable causes are:1) The…
Servo alarms (SV alarm) SV0459 Solutions
Servo alarms (SV alarm) SV0459 Message - SV0459 HI HRV SETTING ERROR Description For two axes whose servo axis numbers…
Servo alarms (SV alarm) SV0458 Solutions
Servo alarms (SV alarm) SV0458 Message - SV0458 CURRENT LOOP ERROR Description The specified current loop differs from the actual…
Servo alarms (SV alarm) SV0456 Solutions
Servo alarms (SV alarm) SV0456 Message - SV0456 ILLEGAL CURRENT LOOP Description An attempt was made to set the current…
Servo alarms (SV alarm) SV0454 Solutions
Servo alarms (SV alarm) SV0454 Message - SV0454 ILLEGAL ROTOR POS DETECT Description The magnetic pole detection function terminated abnormally.The…
Servo alarms (SV alarm) SV0453 Solutions
Servo alarms (SV alarm) SV0453 Message - SV0453 SPC SOFT DISCONNECT ALARM Description Software disconnection alarm of the Pulsecoder.Turn…
Servo alarms (SV alarm) SV0449 Solutions
Servo alarms (SV alarm) SV0449 Message - SV0449 INV. IPM ALARM Description Servo Amplifier : The IPM (Intelligent Power Module)detected…
Servo alarms (SV alarm) SV0448 Solutions
Servo alarms (SV alarm) SV0448 Message - SV0448 UNMATCHED FEEDBACK ALARM Description The sign of the feedback signal from the…
Servo alarms (SV alarm) SV0447 Solutions
Servo alarms (SV alarm) SV0447 Message - SV0447 HARD DISCONNECT(EXT) Description The hardware detected a disconnected separate detector. Drive (…
Servo alarms (SV alarm) SV0446 Solutions
Servo alarms (SV alarm) SV0446 Message - SV0446 HARD DISCONNECT ALARM Description The hardware detected a disconnected built–in Pulsecoder. Drive…
Servo alarms (SV alarm) SV0445 Solutions
Servo alarms (SV alarm) SV0445 Message - SV0445 SOFT DISCONNECT ALARM Description The digital servo software detected a disconnected Pulsecoder.…
Servo alarms (SV alarm) SV0444 Solutions
Servo alarms (SV alarm) SV0444 Message - SV0444 INV. COOLING FAN FAILURE Description Servo Amplifier : Internal cooling fan failure.…
Servo alarms (SV alarm) SV0443 Solutions
Servo alarms (SV alarm) SV0443 Message - SV0443 CNV. COOLING FAN FAILURE Description Power Supply (PS) : Internal cooling fan…
Servo alarms (SV alarm) SV0442 Solutions
Servo alarms (SV alarm) SV0442 Message - SV0442 CNV. CHARGE FAILURE Description Power Supply (PS) : The spare charge circuit…
Servo alarms (SV alarm) SV0441 Solutions
Servo alarms (SV alarm) SV0441 Message - SV0441 ABNORMAL CURRENT OFFSET Description The digital servo software detected an abnormality in…
Servo alarms (SV alarm) SV0440 Solutions
Servo alarms (SV alarm) SV0440 Message - SV0440 CNV. EX DECELERATION POW. Description Power Supply (PS) : Excessive generative discharge…
Servo alarms (SV alarm) SV0439 Solutions
Servo alarms (SV alarm) SV0439 Message - SV0439 CNV. OVER VOLT DC LINK Description Power Supply (PS) : The DC…
Servo alarms (SV alarm) SV0438 Solutions
Servo alarms (SV alarm) SV0438 Message - SV0438 INV. ABNORMAL CURRENT Description Servo Amplifier Drive ( Amplifier ) lowest Repair…
Servo alarms (SV alarm) SV0437 Solutions
Servo alarms (SV alarm) SV0437 Message - SV0437 CNV. OVERCURRENT POWER Description Power Supply (PS) : Overcurrent on input circuit…
Servo alarms (SV alarm) SV0436 Solutions
Servo alarms (SV alarm) SV0436 Message - SV0436 SOFTTHERMAL(OVC) Description The digital servo software detected a software thermal (OVC). Drive…
Servo alarms (SV alarm) SV0435 Solutions
Servo alarms (SV alarm) SV0435 Message - SV0435 INV. LOW VOLT DC LINK Description Servo Amplifier Drive ( Amplifier )…
Servo alarms (SV alarm) SV0434 Solutions
Servo alarms (SV alarm) SV0434 Message - SV0434 INV. LOW VOLT CONTROL Description Servo Amplifier Drive ( Amplifier ) lowest…
Servo alarms (SV alarm) SV0433 Solutions
Servo alarms (SV alarm) SV0433 Message - SV0433 CNV. LOW VOLT DC LINK Description Power Supply (PS) : Low DC…
Servo alarms (SV alarm) SV0432 Solutions
Servo alarms (SV alarm) SV0432 Message - SV0432 CNV. LOW VOLT CONTROL Description Power Supply (PS) : The control power…
Servo alarms (SV alarm) SV0431 Solutions
Servo alarms (SV alarm) SV0431 Message - SV0431 CNV. OVERLOAD Description Power Supply (PS) : Overheat Servo Amplifier : Overheat…
Servo alarms (SV alarm) SV0430 Solutions
Servo alarms (SV alarm) SV0430 Message - SV0430 SV MOTOR OVERHEAT Description The servo motor has overheated. Drive ( Amplifier…
Servo alarms (SV alarm) SV0423 Solutions
Servo alarms (SV alarm) SV0423 Message - SV0423 EXCESS ERROR IN TORQUE Description In torque control, the total permissible move…
Servo alarms (SV alarm) SV0422 Solutions
Servo alarms (SV alarm) SV0422 Message - SV0422 EXCESS VELOCITY IN TORQUE Description In torque control, the commanded permissible velocity…
Servo alarms (SV alarm) SV0421 Solutions
Servo alarms (SV alarm) SV0421 Message - SV0421 EXCESS ERROR(SEMI-FULL) Description The difference between the feedback from the semi and…
Servo alarms (SV alarm) SV0420 Solutions
Servo alarms (SV alarm) SV0420 Message - SV0420 SYNC TORQUE EXCESS Description In feed axis control , for synchronization, the…
Servo alarms (SV alarm) SV0417 Solutions
Servo alarms (SV alarm) SV0417 Message - SV0417 ILL DGTL SERVO PARAMETER Description A digital serve parameter setting is incorrect.…
Servo alarms (SV alarm) SV0415 Solutions
Servo alarms (SV alarm) SV0415 Message - SV0415 MOTION VALUE OVERFLOW Description The velocity exceeding the travel velocity limit was…
Servo alarms (SV alarm) SV0413 Solutions
Servo alarms (SV alarm) SV0413 Message - SV0413 LSI OVERFLOW Description The counter for the amount of positional deviation overflowed…
Servo alarms (SV alarm) SV0411 Solutions
Servo alarms (SV alarm) SV0411 Message - SV0411 EXCESS ERROR (MOVING) Description The amount of positional deviation during traveling became…
Servo alarms (SV alarm) SV0410 Solutions
Servo alarms (SV alarm) SV0410 Message - SV0410 EXCESS ERROR (STOP) Description The amount of positional deviation during stopping exceeded…
Servo alarms (SV alarm) SV0409 Solutions
Servo alarms (SV alarm) SV0409 Message - SV0409 DETECT ABNORMAL TORQUE Description An abnormal load was detected on the servo…
Servo alarms (SV alarm) SV0407 Solutions
Servo alarms (SV alarm) SV0407 Message - SV0407 EXCESS ERROR Description The difference value of the amount of positional deviation…
Servo alarms (SV alarm) SV0404 Solutions
Servo alarms (SV alarm) SV0404 Message - SV0404 IMPROPER V_READY ON Description Although the ready signal (PRDY) of the position…
Servo alarms (SV alarm) SV0403 Solutions
Servo alarms (SV alarm) SV0403 Message - SV0403 CARD/SOFT MISMATCH Description The combination of the axis card and the servo…
Servo alarms (SV alarm) SV0401 Solutions
Servo alarms (SV alarm) SV0401 Message - SV0401 IMPROPER V_READY OFF Description Although the ready signal (PRDY) of the position…
SV0387 ABNORMAL ENCODER(EXT)
SV0387 ABNORMAL ENCODER(EXT) An abnormality occurred on a separate detector. For moreinformation, contact the scale manufacturer.
SV0386 DATA TRANS. ERROR(EXT)
SV0386 DATA TRANS. ERROR(EXT) A CRC error or stop bit error occurred in the communications data from the standalone detector.
SV0385 SERIAL DATA ERROR(EXT)
SV0385 SERIAL DATA ERROR(EXT) - The communications data could not be received from theseparate detector.
SV0384 SOFT PHASE ALARM(EXT)
SV0384 SOFT PHASE ALARM(EXT) - The digital servo software detected abnormal data on theseparate detector.
SV0383 PULSE MISS(EXT)
SV0383 PULSE MISS(EXT) A pulse error occurred on the separate detector.
SV0382 COUNT MISS(EXT)
SV0382 COUNT MISS(EXT) A count error occurred on the separate detector.
SV0381 ABNORMAL PHASE (EXT)
SV0381 ABNORMAL PHASE (EXT) - An abnormal alarm in the position data occurred on theseparate detector.
SV0380 BROKEN LED(EXT)
SV0380 BROKEN LED(EXT) - SV0380 BROKEN LED(EXT)
SV0369 DATA TRANS. ERROR(INT)
SV0369 DATA TRANS. ERROR(INT) - A CRC error or stop bit error occurred in the communications data from the built–in…
SV0368 SERIAL DATA ERROR(INT)
SV0368 SERIAL DATA ERROR(INT) - The communications data could not be received from thebuilt–in Pulsecoder.
SV0367 COUNT MISS(INT)
SV0367 COUNT MISS(INT) - A count error occurred on the built–in Pulsecoder.
SV0366 PULSE MISS(INT)
SV0366 PULSE MISS(INT) - A pulse error occurred on the built–in Pulsecoder.
SV0365 BROKEN LED(INT)
SV0365 BROKEN LED(INT) - The digital servo software detected abnormal data on thebuilt–in Pulsecoder.
SV0364 SOFT PHASE ALARM(INT)
SV0364 SOFT PHASE ALARM(INT) - A digital servo soft detected an abnormality on the built in Pulsecoder.
SV0363 ABNORMAL CLOCK(INT)
SV0363 ABNORMAL CLOCK(INT) - The clock alarm occurred on the built–in Pulsecoder.
SV0362 ABNORMAL REV. DATA(INT)
SV0362 ABNORMAL REV. DATA(INT) The speed count abnormal alarm occurred on the built-in Pulsecoder.
SV0361 ABNORMAL PHASE DATA(INT)
SV0361 ABNORMAL PHASE DATA(INT) - The phase data abnormal alarm occurred on the built–in Pulse coder.
SV0360 ABNORMAL CHECKSUM(INT)
SV0360 ABNORMAL CHECKSUM(INT) - The checksum alarm occurred on the built–in Pulsecoder.
SV0307 APC ALARM: MOVEMENT EXCESS ERROR
SV0307 APC ALARM: MOVEMENT EXCESS ERROR - Since the machine moved excessively, the correct machine position could not be obtained.
SV0306 APC ALARM: OVER FLOW ERROR
SV0306 APC ALARM: OVER FLOW ERROR - Since the amount of positional deviation overflowed, the correct machine position could not…
SV0305 APC ALARM: PULSE ERROR
Since the absolute-position detector caused a pulse error, the correct machine position could not be obtained. The absolute-position detector, or…
SV0304 APC ALARM: PARITY ERROR
Since the absolute-position detector caused a parity error, the correct machine position could not be obtained. (datatransfer error)The absolute-position detector,…
SV0303 APC ALARM: FRAMING ERROR
Since the absolute-position detector caused a framing error, the correct machine position could not be obtained.(data transfer error)The absolute-position detector,…
SV0302 APC ALARM: OVER TIME ERROR
Since the absolute-position detector caused an overtime error, the correct machine position could not be obtained.(data transfer error) The absolute-position…
SV0301 APC ALARM: COMMUNICATION ERROR
Since the absolute-position detector caused a communication error, the correct machine position couldnot be obtained. (data transfer error) The absolute-position…
SV0007 SV ALM ANOTHER PATH(MULTI AMP.)
When a multiaxis amplifier was used in a 2-path system across paths, a servo alarm occurred on an axis belongingto…
SV0006 ILLEGAL TANDEM AXIS
For the slave axis under tandem control, absolute position detection is set (parameter bit 5 (APC) of parameter No. 1815…
SV0005 SYNC EXCESS ERROR (MCN)
In feed axis control , for synchronization, the difference value of the machine coordinate between a master and slave axes…
SV0004 EXCESS ERROR (G31)
The amount of positional deviation during torque limit skip command operation exceeded the limit value of the parameter No.6287.
SV0003 SYNCHRONOUS/COMPOSITE/SUPER IMPOSED CONTROL MODE CAN’T BE CONTINUED
Since as axis in synchronization, composite, or superimposed mode caused a servo alarm, the mode could not be continued, If…
SV0002 SYNC EXCESS ERROR ALARM 2
In feed axis control , the amount of synchronization error exceeded the parameter (No. 8332) setting value. When the synchronization…
SV0001 SYNC ALIGNMENT ERROR
In feed axis control , the amount of compensation for synchronization exceeded the parameter (No. 8325) setting value.This alarm occurs…