For the PSM-5.5i to PSM-15 i
Meaning The main circuit power module (IPM) has detected an abnormal condition.
Steps for troubleshooting
- Control supply voltage decrease of the power module (IPM) Replace the power unit.
- Input supply voltage imbalance Check the input power supply specification.
- The specification of the AC reactor does not match the PSM in use. Check the PSM and the specification of the AC reactor.
- IPM failure Replace the IPM.
For the PSM-15i to PSM-37i
Meaning Over current flowed into the input of the main circuit.
Steps for troubleshooting
- Input supply voltage imbalance Check the input power supply specification.
- The specification of the AC reactor does not match the PSM in use. Check the PSM and the specification of the AC reactor.
- IGBT defective Replace IGBT.
Fanuc power supply amplifier (drive) alarm indicated 01